Basic parameters of the equipment
1. Glass size: maximum: 1100*2000mm; Minimum: 300*300mm;Thickness: 2-6mm, conventional 3.2mm;
2. Glass varieties: solar embossed glass, float glass;
3. The total length of the wire coating equipment is 19M: thepreheating section is about 3.75m, the coating section is about 4.0m, and themain drying passage is about 11.25m.
4. The width of the coating equipment is 2.35m, and the heightis 900±50mm adjustable (the height of the plane on the drum to the ground, theoverall design criterion is the same as the height of the tempering furnace);
5. Temperature requirements: infrared heating tube heatingmethod; Preheating section: adjustable at room temperature -150℃; Hightemperature section: adjustable from normal temperature to 250℃; Furnace temperature steady-state error ≤±2.5℃.
6. The working time of the equipment is 24 hours, and theheating time of the restart is less than or equal to 15min;
7. The transmission line speed is adjustable from 0 to 8m/min
8. Working height: 900 adjustable ±50mm
9. Transfer roll way of main drying furnace is made of ¢50mm ceramic roller of tempering furnace;
10. Main drive adopts double row "O" belt drive.
11. Bearings and bearing seats are made of LK Bearings Co., LTD.
12. Drive motor is made of Jie brand.
13. Pneumatic components are all made of Sanaisi products.
14. The driving parts shall be fully enclosed and visibleprotective cover, which is convenient for disassembly and maintenance.
15. No dust can be produced in the furnace to affect the glasssurface quality. The inner wall of the furnace is made of 1.5mm stainless steelmirror plate.
16. The appearance and cover of the equipment are beautiful. Theupper cover adopts 1.5mm304 stainless steel frosted plate.
17. Frame paint color: RAL7305
18. Electrical requirements
The heating pipe connection should be outside the furnace tofacilitate tube change and wiring.
Buy a TICKET using a Siemens PLC brand, transducers use theSiemens brand, low-voltage appliances use Snade and a touchscreen uses Waylon
Screen and PLC programs are not encrypted and need to provide abackup of final comments.
The maximum load capacity allowance for contactor selectionshould be sufficient during design.
Adjusting the transmission speed automatically shows and changesdirectly on the touch screen, and the deviation from the actual speed can be nomore than 0.01m/min
Lends the heating control mode to PID control
Buy a ticket operation plane: Operators operate between twolines installed in parallel.